MODEL : RD2692

 

  RADAR LEVEL

♦ Application                              : Liquids with high temperature, high pressure and light corrosion.  

♦ Measuring range (Maximum)   : 30m (Depends on dielectric constant of different medium and the concrete working conditions) 

♦ Process connection                  : Thread, Flange  

♦ Process temperature                : -40°C … +250°C  

♦ Process pressure                      : -0.1~4.0MPa 

♦ Accuracy                                  : ±3~15mm 

♦ Repeatability                           :  ±2mm 

♦ Dead band                              : 500mm

♦ Frequency range                     : 26GHz 

♦ Explosion proof                      : Ex ia IIC T6. Exd ia IIC T6 

♦ Enclosure protection grade     : IP67

♦ Signal output                          :  4-20mA/ HART (2-wire/ 4-wire), RS485/ Modbus